Programmed AC Source
The DFC-PAS series AC Source is an ideal frequency converter for AC electric equipment tests, The AC source is equipped with an effective filtering system inside. The DFC-PAS series AC Power Source, especially, suffices for transformers induced voltage tests, it outputs single and three phase voltage 50hz hertz to 500 hertz 1V-1000V, or different frequency and voltage values, flexibly adapt to the electrical testing requirements with mutiple parameters tests conducted.
A stable and adjustable AC power is provided to the equipment, accurately simulating the voltage under different working conditions, our DFC-PAS series AC Source could deliver a clean AC power to the experimental equipment by outputting predetermined frequency and voltage values.
wide Range of Power Ratings (3kVA to 1600kVA)
wide swing range of output voltage in single phase & three phase
galvanically isolated, built in ac power filters
flexibly adapt to the electrical testing requirements
voltage and frequency adjust steps:0.1V/Hz to 10V/Hz
General Specification Datasheet of Programmed AC Source
MODEL NOS. | DFC-PAS-31P100 (No.100 represents power capacity 100kVA) |
---|---|
- Phase: | either Three Phase or Single Phase, 4 Wire (3P+N+GE) / 2 Wire (1P+N+GE) |
- Power Capacity: | 23 Model Ratings: 3kVA,6kVA,10kVA,15kVA,20kVA,30kVA,45kVA,60kVA,75kVA,100kVA,125kVA,150kVA,200kVA,250kVA,300kVA,400kVA,500kVA,600kVA,800kVA,1000kVA,1200kVA,1500kVA & 1600kVA |
- Topology: | Sine Wave Pulse Width Modulated (SPWM) |
INPUT | |
- Number of Phases: | Three Phase & Single Phase |
- Voltage Values: | 380V(L-L)/220V(L-N), accepted customized voltage value |
- Voltage Swing: | ±15% |
- Frequency: | 50Hz/60Hz |
- Frequency Tolerance: | 40 to 70Hz |
- Rectifier: | 6 Pulse |
- Power Factor: | 0.8PF |
OUTPUT | |
-Three Phase & Single Phase: | 0.1V-500.0V ±1%, accepted customized voltage value |
-Voltage Stability: | ≤±1% |
- Frequency: | 40-400Hz adjustable |
- Frequency Stability: | ≤0.02% |
- THD: | Pure Sine Wave Harmonic Distortion:<2% for Linear Loads |
- Overall Efficiency: | ≥85% |
- Front Panel Display: | LCD HMI Digital Display |
- Digital Metering: | Output Frequency, Output Voltage, Current Load(Amps), Load (Watts) or Kilo Watts, Frequency, Voltage, Current, Power Factor, time Setting |
- Programmed Function | multiple groups of data tests can conducted |
- Comm. Interface | RS485/RJ45 etc. |
- Protection: | Complete over current, over load, over heat, short circuit protections and alarm. |
- Overload: | 150% for 30s |
- Noise: | 1 meter 60db to 70 dBA (dependent on model rating) |
- IP Rating: | IP20 / NEMA1 (Option IP54 / NEMA3 ) |
- Dimension&Weight: | Dependent on model rating and configuration.( Please consult to seller ) |
- Certificate: | CE. Reference Standards EN60204, EN61000 |
- Warranty: | 2 Years / 24 Months from date of supply |
-Working Temp.: | -10℃ - 45℃ |
PHYSICAL | Power Connections:cables Input & Output: bottom cable entry for floor mounted converter and converter with castors. |