On-line UPS low-frequency high-frequency UPS

On-line UPS

Online UPS generally adopts a double conversion toplogy. The so-called dual conversion refers to the process in which the electrical energy of a UPS undergoes two transformations, AC/DC and DC/AC, before being supplied to the load during normal operation. The UPS keeps its inverter in working condition, first converting external AC power into DC power through the circuit, and then converting the DC power into high-quality sine wave AC power through a high-quality inverter to output to the load. The online UPS under working conditions could output a stabilized voltage and manage batteries charging; During a power outage, the backup DC power source (battery packs) to supply power to the inverter. Due to the continuous opera tion of the inverter, there is no switching time issue, making it suitable for situations with strict requirements for the power supply. We offer two kinds of UPS, one Low-frequency UPS and another High-frequency UPS. 

Low-frequency UPS has strong impact and overload resistance competence as a result of isolation transformers built, it’s good load adaptability, and are particularly suit able for inductive loads (such as motors), industrial environments, heavy-duty equipment and harsh environments.

High-frequency UPS does not require a insolation transformer. The input usually has a PFC circuit. The input power factor can reach to 0.99, which is highly efficient, energy-saving, and significantly improves overall efficiency; Small in size and lightweight, suitable for loads such as conventional IT equipment (servers, storage, network devices) and precision instruments.

Key Benefits

  • High efficiency
  • Maintenance free
  • Adapt to all kind of load.
  • Availble in parallel operation
  • Digital control to achieve online double conversion
  • Remote control optional – communication interfaces

General Specification of On-line UPS

MODEL NOS.DLF-63-30-X* or DGP-63-40-X*
- Phase3 Phase 4 Wire (3P+N+GE)Option
- Power Rating10kVA,15kVA,20kVA,30kVA,40kVA,50kVA,60kVA,80kVA,100kVA,120kVA,160kVA,200kVA
- Battery Back-up TimeDefault: 15-30 Mins; 30 Mins-120 Mins Optional
INPUT
- Nominal Voltage208Vac...380Vac/400Vac/415Vac...480Vac(L-L) *Select One Voltage Value"
- Voltage SwingNominal Voltage ±15%
- Frequency50Hz / 60Hz
- Frequency SwingNominal Freq. ±10%
- Power Factor0.8 PF for Low-frequency UPS; 0.99 PF Low-frequency UPS
OUTPUT
- Voltage208Vac...380Vac/400Vac/415Vac...480Vac(L-L) *Select One Voltage Value"
- Voltage Stability≤ ±1% Static Mode
- Dynamic Voltage TransientTypical value ≤ ±5% (Output 0-50%-100%,recovery time≤20ms)
- Frequency50Hz/60Hz
- Frequency Stability±0.1%Batteries Mode
- Front Panel Display:4 Digital Display & Control Panel with Phase Selector (L-N voltage & L-L voltage metering switch) and On / Off Push Buttons
- Wave FormPure Sine Wave
- THDHarmonic Distortion:≤2% for Linear Loads
- Overload Competence125% 10minutes; 150% 1 minute
- Overall Efficiency90% - 93%
- Front Panel DisplayLCD: 4 Digital Display & Control Panel, Input & Output Voltage. Frequency,Battery Voltage,Power meter.
- IndicatorsMains electricity, Inverter, Bypass, Battery,Falut,Overload etc.
- InterfaceRS232/RS485, CAN, SNMP...
-BypassStatic Switch; Microprocessor Control, Synchronous mode - switching uninterrupted
- Battery TypeSealed lead-acid batteries, DC Voltage: 192VDC,240VDC,384VDC,480VDC... DC voltage value choosen as per Back-up time
- PhysicalIP20 / NEMA 1 (Tailor-made for individual request); Cables Input & Output with bottom cable entry
- Dimension & WeightDependent on model rating and back-up time
- Working Tempminus 10% to +45℃
- Warranty1 Years / 12 Months from date of supply

Working Principle Block Diagram

  • Normal working mode (From Mains Electricity): Mains electricity → Rectifier → Inverter → Load.
  • Battery working mode (Abnormal – Power Outage): Battery → Inverter → Load.
  • Bypass working mode (UPS internal fault or overload): Mains electricity → Static bypass switch → Load.
On-line UPS working principle diagram SLD